Detection of Abnormal Fetuses Using Biorthogonal Wavelet Analysis

Authors

  • Rand Kasim Mohammed medical engineering, Dyiala University /college of medicine

Keywords:

Biorthogonal Wavelet Analysis

Abstract

Biomedical signals are generated by complex self-regulating systems that process inputs with a broad range of characteristics. Many physiological time series, such as the fetal heart rate, are extremely inhomogeneous and nonstationary, fluctuating in an irregular and complex manner. In this project, the amplitude of low-frequency fluctuation of fetal heart rate frequency was studied using analysis called wavelet transform. The nature and maturational changes of lowfrequency fluctuation of the FHR in normal fetuses were investigated and probability distribution of FHR wavelet coefficients was studied from 28 wk of gestation onward. The value of the parameter a of this distribution did not exceed 1.939 regardless of the gestational age in a normal condition. The value of index a range from 2.1585 up to 3.1652 in fetuses from pregnant women with pregnancy-induced hypertension. This project also presents a system capable of

calculating index for the fetal heart rate lowfrequency fluctuation distribution value and uses it to identify the fetus condition using the MATLAB 7.3 package.

FHR data of 12 normal fetuses and 18 fetuses from pregnant women with pregnancyinduced hypertension all between 28 and 38weeks of gestation were studied. First, the cardiotocography tracing was converted from CTG paper images into digital series using image processing so that the system can analyze it. The FHR was then converted to inter-heart beat time series. Biorthogonal wavelet transform was used to analyze interheart beat time series. The histogram of the absolute value of resulting wavelet coefficients was analyzed then probability distribution of wavelet coefficients frequency was used to calculate the fluctuation parameter a. Statistical analysis methods where used to compare between the results. The Kruskal- Wallis test was used to test the significance of

the difference among the parameters obtained; Pearson s test was used to test goodness of fit of the distribution function. In addition, the t-test was used for other statistics. Index a values were used in last stage of the system to identify sick fetuses. When analyzing fetal heart rate of 18 fetuses from pregnant women with pregnancy-induced hypertension the system succeed to identify the presence of a problem in 6 fetuse

Downloads

Download data is not yet available.

Downloads

Published

04-03-2008

How to Cite

[1]
R. K. Mohammed, “Detection of Abnormal Fetuses Using Biorthogonal Wavelet Analysis”, NJES, vol. 11, no. 1, pp. 153–160, Mar. 2008, Accessed: Nov. 25, 2024. [Online]. Available: https://nahje.com/index.php/main/article/view/507

Similar Articles

161-170 of 170

You may also start an advanced similarity search for this article.