Fatigue and Vibration Parameters Improvement of Steel DIN 41Cr4 by Ultrasonic Shock Peening Treatment
DOI:
https://doi.org/10.29194/NJES.2203233Keywords:
Ultrasonic Peening, Fatigue Life and Fatigue Limit, Alloy Steel DIN 41Cr4Abstract
The effects of the ultrasonic peening treatment (UPT) on the rotating bending fatigue behavior and the behavior of the vibrations of alloy steel DIN 41Cr4 were studied. Hardness test, Tensile test, Constant amplitude fatigue tests, and the vibrations measurements have been carried out on the specimens. Also, the fracture surface was examined and analyzed by a Scanning Electron Microscope (SEM). The results of the investigations, e.g. stress to number of cycles to failure (S-N) curves, fatigue strength improvement factor was 7%. The decreasing percentage of maximum Fast Fourier Transform (FFT) acceleration of the ultrasonic peened condition compared to the untreated conditions was 45%.
Downloads
Downloads
Published
Issue
Section
License
The authors retain the copyright of their manuscript by submitting the work to this journal, and all open access articles are distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International (CC-BY-NC 4.0), which permits use for any non-commercial purpose, distribution, and reproduction in any medium, provided that the original work is properly cited.