The Characteristic Performance of Fluidized bed Ion Exchange

Authors

  • Malik M. Mohamed Biochemical Engineering Department AL-Khwarizmi College OF Engineering
  • Nahidh W. Kaseer Chemical Engineering Department College of Engineering Nahrain Unversity
  • Iman Haider Mahdi Chemical Engineering Department College of Engineering Nahrain Unversity

Keywords:

Fluidization, Ion Exchange

Abstract

The aim of this work is to study the characterization of ion exchange in important characteristics (i.e., breakthrough time and exchange capacity) by investigation the performance of cation exchange column subjected to makeup solution in term of three different parameter (i.e., bed depth 5-45cm, NaCl salt concentration100-2000 ppm and feed flow rate 9.5-26.5l/h). Two second order polynomial model are proposed with Box Wilson composite rotatable

design. The experimental result had shown an efficient performance of using ion exchange column with strong acid cation exchange resin in fluidized mode operation which given maximum breakthrough time and higher exchange capacity means the rate of exchange is very rapid to completed the

removing of all undesired ions at a condition of low bed depth, high NaCl concentration and high feed flow rate.

Downloads

Download data is not yet available.

Downloads

Published

20-03-2009

How to Cite

[1]
M. M. Mohamed, N. W. Kaseer, and I. H. Mahdi, “The Characteristic Performance of Fluidized bed Ion Exchange”, NJES, vol. 12, no. 1, pp. 38–46, Mar. 2009, Accessed: Nov. 25, 2024. [Online]. Available: https://nahje.com/index.php/main/article/view/562

Similar Articles

81-90 of 404

You may also start an advanced similarity search for this article.