Enhancement Wear Resistance of Carbon Dual Phase Steel by Cryogenic Treatment

Authors

  • Abbas A. Hussein Baghdad University / Mech. Eng. Dep., Baghdad-Iraq
  • Hussein B. Muhammad Diyala University / Mech. Eng. Dep., Diyala -Iraq

Keywords:

wear, cryogenic treatment, dual phase steel

Abstract

Dual phase steels containing three different amounts of martensite 21, 37 and 87 Vol. Pct. have been made from carbon steels containing 0.12, 0.33 and 0.43 wt. pct. Carbon respectively. Intercritical annealing treatment at 760 ºC was employed, followed by quenching in Brine. Cryogenic treatment was carried out using liquid nitrogen. Dry sliding wear tests have been conducted on Dual phase (DP) steels before and after cryogenic treatment, using a pin-on disk machine under load 25 N and at a constant sliding velocity 1.74 m/s, for 10 min. at room temperature. Wear properties have been found to improve with the increase in martensite volume fraction in dual phase steels, also, it was observed that, after cryogenic treatment the wear resistance of dual phase steel has improved.

Downloads

Download data is not yet available.

Downloads

Published

01-06-2014

How to Cite

[1]
A. A. Hussein and H. B. Muhammad, “Enhancement Wear Resistance of Carbon Dual Phase Steel by Cryogenic Treatment”, NJES, vol. 17, no. 2, pp. 173–178, Jun. 2014, Accessed: Nov. 24, 2024. [Online]. Available: https://nahje.com/index.php/main/article/view/219

Similar Articles

51-60 of 162

You may also start an advanced similarity search for this article.