Go to Editorial ManagerIn this paper, the cross section behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) under concentric and eccentric vertical load was study. The casted columns were cured in two different type tap water for 28 days and chloride water for six months. Chloride salts with concentration was 8341.6 mg/l. Three variables were adopted in the experimental program; concrete type, curing type and the eccentricity of vertical load. Twenty (120x120x1200) mm columns were casted and tested depending on these variables. The different eccentricities were (0, 50,100 and 150) mm and where (e/h) were (0, 0.42, 0.83 and 1.25) respectively from the center of column, the other types of loading are tested the specimens as beam._x000D_ The experimental results showed increasing in ultimate load capacity and higher chlorides resisting for hybrid reactive powder concrete in comparison with normal concrete in both types of curing (tap and chloride water). Through studying load deflection, test results for Normal Strength Concrete (NSC) and Hybrid Fiber Reactive Powder Concrete (HFRPC) columns that deflection for columns cured in chloride water more than tap water when compared at the same load that also by increase eccentricity leads to an increase in deflection for both cured and The neutral axis depth for HFRPC columns is more than NSC at the same load also when eccentricity increases, the compression zone decreases and neutral axis also decrease by increase eccentricity. These results occur when columns are cured in tap and chloride water._x000D_
This paper studies the effect of different design spectral response acceleration parameters as suggested by the uniform building code (UBC), unified facilities criteria (UFC), and Iraqi seismic code(1997) (ISC 97) on the seismic response of reinforced concrete multi-story framed building located in Baghdad city, Iraq. These parameters are: (a) spectral response accelerations Ss, at short periods, and S1 at a 1-second period in accordance with international building code (IBC), (b) seismic zone factor (Z) according to UBC, (c) Seismic hazard zoning coefficient (Z) according to ISC 97. In this paper, first, the elastic seismic responses for significant modes of vibration for chosen building under design response spectrum that obtained from the above mentioned codes are calculated, and then a comparison was made among different design spectral response acceleration parameters. The intent of this study is to review the seismic provisions of the current edition of Iraqi seismic code (1997) to determine whether it provides an equivalent level of safety to that contained in other international codes. Design base shears, lateral seismic forces, inter story drifts, response spectrum modal, effective seismic modification, floors acceleration and story shears are comparatively presented.
In this study, previous researches were reviewed in relation to the seismic evaluation and retrofitting of an existing building. In recent years, a considerable number of researches has been undertaken to determine the performance of buildings during the seismic events. Performance based seismic design is a modern approach to earthquake resistant design of reinforcement concrete buildings. Performance based design of building structures requires rigorous non-linear static analysis. In general, nonlinear static analysis or pushover analysis was conducted as an efficient instrument for performance-based design. Pushover analysis came into practice after 1970 year. During the seismic event, a nonlinear static analysis or pushover analysis is used to analyze building under gravity loads and monotonically increasing lateral forces. These building were evaluated until a target displacement reached. Pushover analysis provides a better understanding of buildings seismic performance, also it traces the progression of damage and failure of structural components of buildings.
In this paper an experimental works conducted to study the behavior of R.C. beam with large web opening at different locations and fortified with reactive powder composite (RPC) at the extreme tension zone (bottom edge of opening) and/or extreme compression zone (Top edge of opening). The experimental study is investigate the behavior of twelve beams and study the ability of using normal strength concrete together with RPC in the same section to exploit the advantages of these two materials in optimal way. The main variables are RPC layers locations in tension zone and/or in compression zone and the locations of openings. The ultimate loads, load mid-span deflection behavior and strain for steel and concrete were discussed. The experimental results showed that the ultimate strength was decreased with increasing number of opening about 4% for beams with two openings located in shear zone and 21% for beams with three openings, thus indicating that the stiffness decreases accordingly. The using RPC layers effectively enhanced performance of hybrid beams when compared with using the normal strength concrete layers only. The using RPC layers in compression and tension zones increased the ultimate load about 47 % for beams with two opening located in shear zone, when using RPC in the tension zone and normal strength concrete in the compression zone the ultimate flexural load and ultimate deflection increase little compared with normal concrete.