Vol. 21 No. 3 (2018) Cover Image
Vol. 21 No. 3 (2018)

Published: September 30, 2018

Pages: 327-343

Articles

Behavior of Hybrid Reactive Powder Concrete Columns Exposed to Chloride Attack

Abstract

In this paper, the cross section behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) under concentric and eccentric vertical load was study. The casted columns were cured in two different type tap water for 28 days and chloride water for six months. Chloride salts with concentration was 8341.6 mg/l. Three variables were adopted in the experimental program; concrete type, curing type and the eccentricity of vertical load. Twenty (120x120x1200) mm columns were casted and tested depending on these variables. The different eccentricities were (0, 50,100 and 150) mm and where (e/h) were (0, 0.42, 0.83 and 1.25) respectively from the center of column, the other types of loading are tested the specimens as beam._x000D_ The experimental results showed increasing in ultimate load capacity and higher chlorides resisting for hybrid reactive powder concrete in comparison with normal concrete in both types of curing (tap and chloride water). Through studying load deflection, test results for Normal Strength Concrete (NSC) and Hybrid Fiber Reactive Powder Concrete (HFRPC) columns that deflection for columns cured in chloride water more than tap water when compared at the same load that also by increase eccentricity leads to an increase in deflection for both cured and The neutral axis depth for HFRPC columns is more than NSC at the same load also when eccentricity increases, the compression zone decreases and neutral axis also decrease by increase eccentricity. These results occur when columns are cured in tap and chloride water._x000D_  

References

  1. Abtan, Y.G.,"Behavior of Reactive Powde Concrete Columns Under Eccentric Compression Loading" Diyala Journal of Engineering Sciences Vol. 07, No. 03, pp. 45- 64, 2014.
  2. Muthuswamy, K.R., and Thirugnanam, G.S., " Experimental Investigation on Behavior of Hybrid Fiber Reinforced Concrete Column Under Axial Loading" ASIAN Journal of Civil Engineering (BHRC) Vol. 15, No. 2, pp. 169-178, (2014).
  3. ACI Committee 318, 2014, Building Code Requirement for Structural Concrete and Commentary, American Concrete, pp.35
  4. ASTM A615, 2005, Standard Specification for Deformed and Plain Carbon Structural Steel Bars for Concrete Reinforcement, Annual Book of ASTM Standards, Vol.01, No.02.
  5. Sarsam, K.F. and Mohammed, M.H.,"Flexural Strength of Hybrid Beams Containing Reactive Powder Concrete and Conventional Concrete", Journal of Engineering and Development, Vol.18, No.5, pp.61-91, 2014.
  6. AL- Saraj, W.K., "Structural Behavior of Reinforced Reactive Powder Concrete T-Beams under Pure Torsion", Ph.D. thesis, University of Mustansiriayah, Iraq, 2013.
  7. Al-Shafii, N.T.H., "Shear Behaviour of Reactive Powder Concrete T-Beams", Ph.D. thesis, University of Mustansiriayah, Iraq, 2013.
  8. Abdulla, N.A., 2007, Effect of Saline Environment on the Strength of Reinforced Concrete Beams, AL-Rafdain Engineering Journal, Vol.16, No.2, pp.1-23.
  9. Selina, R.G., Geethanali, C., Varghese, J. and Pria, P.M. "Influence of Hybrid Fiber on Reinforced Concrete", International Journal Advanced Structures and Geotechnical Engineering, Vol. 03, No. 01, pp. 40-43, 2014