The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerStructural elements. This means the structural behavior can be quantified by considering the behavior of each structural element in each load path. Concrete is a material known for its great strength. Regardless, there are a few weaknesses, which must be taken in consideration in the design of concrete structural elements. Basically, concrete is made of three main ingredients: Portland cement, water, and aggregates (sand and stone).In order to improve tensile strength and ductility (capacity to stretch and deform prior to failure) in concrete, so this paper discus some types of concrete and record the effect on beams. Reactive powder concrete (RPC) is an actual concrete mixture, it is a special type of concrete because mix concrete (coarse and fine aggregate ) replaced by fine sand size (150-400)µm. In the experimental comparison the mechanical properties( compressive , splitting tensile and flexural )strength of plain RPC and high and normal strength concrete. Each set consisted of (4) cubes of (100×100×100_mm, (8) cylinder of (150×300mm) and (4) prism of (100x100x500) mm and consisted of (4) beam of (1000×100×400)mm. The results shown that the maximum compressive strength is 107 MPa and the maximum splitting tensile 9 MPa of RPC comparison high and normal strength concrete. The result of the second part shown increased RPC reinforced concrete the firstcrack288 MPa and ultimate crack 380MPa comparison high and normal strength concrete and the mode of failure of RPC (flexural-shear).
In this paper an experimental works conducted to study the behavior of R.C. beam with large web opening at different locations and fortified with reactive powder composite (RPC) at the extreme tension zone (bottom edge of opening) and/or extreme compression zone (Top edge of opening). The experimental study is investigate the behavior of twelve beams and study the ability of using normal strength concrete together with RPC in the same section to exploit the advantages of these two materials in optimal way. The main variables are RPC layers locations in tension zone and/or in compression zone and the locations of openings. The ultimate loads, load mid-span deflection behavior and strain for steel and concrete were discussed. The experimental results showed that the ultimate strength was decreased with increasing number of opening about 4% for beams with two openings located in shear zone and 21% for beams with three openings, thus indicating that the stiffness decreases accordingly. The using RPC layers effectively enhanced performance of hybrid beams when compared with using the normal strength concrete layers only. The using RPC layers in compression and tension zones increased the ultimate load about 47 % for beams with two opening located in shear zone, when using RPC in the tension zone and normal strength concrete in the compression zone the ultimate flexural load and ultimate deflection increase little compared with normal concrete.
In this paper, the cross section behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) under concentric and eccentric vertical load was study. The casted columns were cured in two different type tap water for 28 days and chloride water for six months. Chloride salts with concentration was 8341.6 mg/l. Three variables were adopted in the experimental program; concrete type, curing type and the eccentricity of vertical load. Twenty (120x120x1200) mm columns were casted and tested depending on these variables. The different eccentricities were (0, 50,100 and 150) mm and where (e/h) were (0, 0.42, 0.83 and 1.25) respectively from the center of column, the other types of loading are tested the specimens as beam._x000D_ The experimental results showed increasing in ultimate load capacity and higher chlorides resisting for hybrid reactive powder concrete in comparison with normal concrete in both types of curing (tap and chloride water). Through studying load deflection, test results for Normal Strength Concrete (NSC) and Hybrid Fiber Reactive Powder Concrete (HFRPC) columns that deflection for columns cured in chloride water more than tap water when compared at the same load that also by increase eccentricity leads to an increase in deflection for both cured and The neutral axis depth for HFRPC columns is more than NSC at the same load also when eccentricity increases, the compression zone decreases and neutral axis also decrease by increase eccentricity. These results occur when columns are cured in tap and chloride water._x000D_
The main objective of the present paper is to investigate the effect of fineness moduli (FM) of fine aggregate on fresh properties (flow ability. Passing ability and segregation resistance), and hardened properties (compressive strength, split tensile strength, flexural strength and ultrasonic pulse velocity UPV) of self-compacting concrete (SCC). Four values of FM 2.3, 2.5, 2.7 and 3.1 were used, according to acceptance range of ASTM C33-03 for FM for fine aggregate, which recommended range for FM is 2.3 to 3.1._x000D_ Four series of mixes were casting , each series consist of two mixes represent normal strength and high strength SCC, each series of mixes made from fine aggregate have the same FM. Flow ability, passing ability.and segregation resistance of fresh SCC, both with normal and high strength decreases with increasing the fineness moduli. High strength SCC more effected than normal strength concrete due to increase the volume of particles. _x000D_ Great enhancement in compressive strength split tensile strength and flexural strength in both normal and high strength SCC when the FM is 2.5. Increase FM to 2.7 and 3.1 not lead to increase in strengths. The UPV values of normal and high strength SCC mixes have a good general condition. SCC mixes with FM 2.5 possess excellent general conditions.
Normal concrete is weak against tensile strength, has low ductility and also insignificant resistance to cracking. The addition of diverse types of fibers at specific proportions can enhance the mechanical properties as well as the durability. Discrete fiber, which is commonly used, have many disadvantages such as balling the fiber, random distribution, and limitation of the used Vf ratio. Based on this vision, a new technique was discovered, enhancing concrete by textile-fiber to avoid all the problems mentioned above. This paper presents all important consequence and conclusions obtained from previous studies on how to strengthen concrete with two-dimensional and three-dimensional textile-fibers, and focuses on the flexural behavior of concrete members. The results indicate that there was an improvement in flexural strength, deformation capacity, and toughness with different load conditions when using different types of textile-fiber. It was observed that the effect of textile-fibers would increase when this fiber was coated by epoxy. In TRC system, there is a significant impact on the number of textile-fiber layers used.