Go to Editorial ManagerRecently, major part of convection heat transfer researches focus on increasing fins efficiency by increasing thermal performance for the same fin volume. Metal foam is a promising way to achieve this aim. Performance analysis has been carried out to investigate the heat transfer characteristics of copper fin foam samples. The samples have been compared with the solid metal fin heat transfer. A forced convection heat transfer had been applied to a four specimens. An electrical heater heats up the fins, which are subjected to a stream of the ambient air driven by a blower fan as heat dissipated. The heat flux had been fixed along the tests with three different air velocity used; the forced heat convection had been simulated. The pores density of copper fin foam is varied in the range of 10, 20 & 40 pores per inches (PPI). Thermal performance of copper fin foam has been evaluated in terms of average Nusselt number and thermal resistance of heat sinks. The increasing in the heat transfer rate and average Nusselt number when used metal foam has been found in the range of 36-133 % compare to solid copper. Furthermore, it has been proven that this increment reaches the maximum value for a given PPI even when raise the air velocity.
An experimental investigation has been performed to study the effect of combined artificially roughened (ribs) with and without single Large Eddy Break-Up Devices, on flow and heat transfer characteristic of fully developed turbulent flow in rectangular duct. The aspect ratio of rectangular duct is 10, hydraulic diameter 72.72 mm, relative roughness pitch (P/e) 10 and relative roughness height (e/Dh) 0.05. The rib was in the form of circular shape with diameter of (4mm) which was mounted on heated wall of duct at spanwise direction. The experiments have been conducted by varying airflow rate in terms of Reynolds number ranging from 3.2x104 to 6.2x104 and constant heat flux of 600W/m2. The heat transfer and friction factor of the flow for rib and combined method were compared with those of a smooth duct under similar experimental conditions. It has been found that the combined method (rib with single Large Eddy Break-Up Devices) has significant effect on the friction factor and heat transfer with decreasing in friction factor with percent(1.2) and increasing Nusselt number with (4.1). Correlations for Nusselt number and friction factor in terms of (Reynolds number and Large Eddy Break-Up Devices) parameters are found which reasonably correlate the experimental data.
In this work , experimental investigation has been done for free-convection heat transfer from rectangular fins array on a heated horizontal base plate to surrounding air in the steady-state flow condition with rectangular notch portion effects. Five cases of fins arrays have been employed . One case without notch and other cases with rectangular notches for different percentages of aspect ratio area removal from fin . The horizontal base plate has been heated with various electrical supplied power values. Different number of fins and spacing have been used . The effect of notches from fins on average convection heat transfer coefficient and average Nusselt number at constant aspect ratio of fin height to fin length and varying heat inputs to the heating element have been discussed . The experimental results show that the performance of notched fins array in term of average convection heat transfer coefficient is 28% to 45% higher than unnotched fins array. The present experimental results have been compared with previously works . The results show a good a greement.
An experimental and theoretical study of free convection heat transfer for a cylinder placed in an iron test section of dimensions (0.2x0.2x0.2 m3), the test section filled with saturated porous material glass balls (5 mm), and the air is the working fluid with Raleigh number (7692.6 ? Ra ? 17654). The circular cylinder heater (D = 0.015 m, L = 0.2 m) is heated electrically, made of Copper and located in different positions (in X & Y direction). The theoretical part includes solving the free convection heat transfer using the ANSYS program (fluent). The experimental and theoretical results showed that the surface temperature values around the cylinder perimeter when changing its position within the test section are changing as moving up and down where the effect of buoyancy force appears. The maximum difference between the upper and lower position at the experimental result is 7.22%, and the average Nusselt number increases with Raleigh number and heat flux. Also, the experimental results showed that the use of porous material significantly improves the heat transfer by 48.6%. The maximum percentage change between the experimental and theoretical results is 5.46%. Moreover, experimental correlations were achieved, and a comparison was performed between the present results with the previous studies and it gives a good agreement.
Natural convection air heat transfer and fluid movement currents around a hot circular cylinder inside an inclined triangular enclosure has been analyzed experimentally. Three different sizes of an enclosure with a long side of 20, 25, and 30 cm, the thickness of 1 mm, and depth of 50 cm were used in the present work to give three radius ratios. The effect of Rayleigh number, radius ratio, the rotation angle of triangle enclosure, and the inclination angle of the apparatus with horizontal axis ? on the heat transfer process was investigated. The ranges of these parameters were: Rayleigh number from 5×106 to 2.5×108, radius ratio (0.345, 0.455, and 0.618), rotation angle (0o, 45o, and 90o), and inclination angle (0o, 45o and 90o). The results show that the heat transfer rates increase with increase in Rayleigh number and as the rotation angle of enclosure is changed from 0o to 90o. Moreover, the heat transfer rate increases linearly with Rayleigh number at higher radius at rotation angle 0o, 90o only. While, it increases slightly with Rayleigh number at rotation angle 45o. Additionally, the higher heat transfer rates occur at vertical position of enclosure inclination angle 90o and rotation angle 0o (the base of triangle at the bottom) and it decreases as inclination angle deviates from 90o to 0o. This behavior is reverse completely at higher radius ratio 0.618. Empirical correlations for the average Nusselt number has been found to depend on Rayleigh number., radius ratio, rotation angle and inclination angle.
A numerical study was performed of natural laminar convective heat transfer to its concentrated triangular enclosure around a horizontal circular cylinder. The air-filled enclosure kept the inner and outer cylinders at uniform temperatures. The Boussinesq density approximation to the momentum problem and the control volume approach iteratively resolved the governing equations to explain buoyancy. CFD results show that the velocity behavior increases by increasing Ra, so the stream lines becomes more sluggish and less uniform behavior and vortices gets less circulated pattern. The rotation angle ? has significant effect on vortices, at 90o gives the higher range of velocity zones of free convection with higher range. The thermal boundary layer seems to be larger in rr=0.455 as compared with rr=0.345 and decreases by increasing ?. The larger variation of isotherms and thermal boundary layer appears at lower ? because the higher heat transfer rate occurs at higher ? and becomes maximum at 90o. Eight correlations of average Nusselt number have been deduced as a function of Rayleigh number for the taken values of aspect ratio and enclosure angles of rotation and inclination.
An experimental study has been carried out to investigate the effects of stainless-steel balls on forced convection flow in pipe under uniform heat flux. Water is used as the working fluid and stainless-steel balls as a porous media. The Reynolds number range from (5000 to 9000) based on the diameter of the pipe. The experiments were conducted on three various numbers of stainless-steel balls (N) with various diameters (dp), which give various porosity (0.33, 0.38 and 0.41). These are (N= 2400, dp=1mm), (N=1600, dp=3mm) and (N= 750, dp=5mm). Results show that, heat transfer coefficient increases with the decrease in the porosity due to the reduction in the space between balls. This led to an increase in turbulence and produced eddies. Furthermore, enhancement in heat transfer coefficient reached its maximum value of (45%) for ball diameter with (dp=1mm) and water flow rate (9 L/min). New Correlation equations for the average heat transfer coefficient were obtained for three different diameters of balls (1, 3 and 5 mm).