Vol. 20 No. 1 (2017) Cover Image
Vol. 20 No. 1 (2017)

Published: January 31, 2017

Pages: 281-291

Articles

The Combined Effect of Rib with Single Large Eddy Break Up Devices on Flow and Heat Transfer Characteristic of Turbulent Flow in Rectangular Duct

Abstract

An experimental investigation has been performed to study the effect of combined artificially roughened (ribs) with and without single Large Eddy Break-Up Devices, on flow and heat transfer characteristic of fully developed turbulent flow in rectangular duct. The aspect ratio of rectangular duct is 10, hydraulic diameter 72.72 mm, relative roughness pitch (P/e) 10 and relative roughness height (e/Dh) 0.05. The rib was in the form of circular shape with diameter of (4mm) which was mounted on heated wall of duct at spanwise direction. The experiments have been conducted by varying airflow rate in terms of Reynolds number ranging from 3.2x104 to 6.2x104 and constant heat flux of 600W/m2. The heat transfer and friction factor of the flow for rib and combined method were compared with those of a smooth duct under similar experimental conditions. It has been found that the combined method (rib with single Large Eddy Break-Up Devices) has significant effect on the friction factor and heat transfer with decreasing in friction factor with percent(1.2) and increasing Nusselt number with (4.1). Correlations for Nusselt number and friction factor in terms of (Reynolds number and Large Eddy Break-Up Devices) parameters are found which reasonably correlate the experimental data.

References

  1. Kral L.D. (1999)" Active Flow Control Technology" Washington University, ASME Fluids Engineering Division Technical Brief.
  2. SriHarsha V.,Prabhu S. V.and Vedula J. C." Influence of rib height on the local heat transfer distribution and pressure drop in a square channel with 90o continuous and 60o V-broken ribs" Applied Thermal Engineering 29 , pp.2444–2459,2009.
  3. Kumar A., Saini R. P. and Saini J. S. "Experimental Investigations on Thermo-hydraulic Performance due to Flow- Attack- angle in Multiple V-ribs with Gap in a Rectangular Duct of Solar Air Heaters" , Journal of Sustainable Energy & Environment 4 , 1-7,2013.
  4. Madhukeshwara and Prakash E.S.(2013) "An Investigation of heat transfer Enhancement and Friction Characteristics in Solar Air Heater Duct with Cube Shaped Uniform Roughness on the Absorber Plate" International Journal of Mechanical Engineering (IJME) ISSN 2319-2240 Vol. 2.
  5. Lee D. H.,Dong R. H.,Kyung M. K.,Hyung H. H.,and Hee K. M.(2009)" Detailed measurement of heat/mass transfer with continuous and multiple V-shaped ribs in rectangular channel" Energy 34 , pp.1770–1778.
  6. Tanda G.(2011) " Effect of rib spacing on heat transfer and friction in a rectangular channel with 45o angled rib turbulators on one/two walls" University of Genova, via Montallegro, 1, I-16145 Genova, Italy, International Journal of Heat and Mass Transfer 54 ,pp. 1081–1090.
  7. Aharwal K. R.,Gandhi B. K. and Saini J. S.(2007)" Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater" Renewable Energy 33 ,pp. 585–596.
  8. Baraskar S. ,Aharwal K. R. and Lanjewar A.(2012)" Experimental Investigation of Heat Transfer and Friction Factor of V-shaped Rib Roughed Duct with and without Gap" International Journal of Engineering Research and Applications , Vol. 2, Issue 6, November- December , pp. 1024-1031.
  9. Roth K.W. and Leeliey P. (1989) " Velocity Profile and Wall Shear Stress Measurements for A Large Eddy Break up Devices(LEBU)"thesis, Acoustics and Vibration Laboratory.
  10. Hollis P. G., LAl J. C .S. and Bullock K. J.(1992)" studies what happens if a LEBU device is inserted in the inner wall region"11th Australasion Fluid Mechanics Conference.
  11. Kuzenkov V. R, Levitskii V. N., Repik E. U. and Sosedko .Yu. F. (1996)" Investigation of the mechanism of surface turbulent friction reduction by means of Large Eddy Break up Devices" Fluid Dynamic Vol. 31, No. 5.
  12. Sommer S. T. and Petrie H. L.(1992) " Diffusion of slot injected drag-reducing polymer solution in a LEBU modified turbulent boundary layer" Applied Research Laboratory, State College, PA 16804, USA, Experiments in Fluids 12,pp. 181-188 .
  13. Inaoka K. and Suzuki K.(1996)" Structure of the Turbulent Boundary Layer and Heat Transfer Downstream of a Vortex Generator Attached to a LEBU Plate " Turbulent Shear Flows 9, Department of Mechanical Engineering, Kyoto University, Kyoto .Japan, 606-01.
  14. Gudilin I. V., Lashkov. Yu. A. and Shumilkin V. G.(1995) " Combined effect of longitudinal riblets and LEBU-Devices on turbulent friction on a plate" fluid Dynamic, Vol.30, No. 3.
  15. Lien K.,Monty P.,Chong M.S. and Ooi A.(2004) "The Entrance Length for Fully Developed Turbulent Channel Flow"The University of Sydney, Sydney, Australia, 15th Australasian Fluid Mechanics Conference, pp.13–17 December .
  16. Head M. R.and Ram V.(1971)"Simplified Presentation of Preston Tube Calibration",Aeronautical Quarterly, Vol. 22, pp. 295-300.
  17. Chompookham T. and Thianpong C.(2010) " Heat transfer augmentation in a wedge-ribbed channel using winglet vortex generators" International Communications in Heat and Mass Transfer 37,pp. 163–169.
  18. Coleman H. W. and Steele W.G.(1999)" Experimentation and Uncertainty Analysis for Engineers" John Wiley and Sons Inc.Second Edition ,New York.
  19. Subramanian R. S.(2014) "Heat transfer in Flow through Conduits" Clarkson University.