×
The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerIn this research the behavior of cylindrical shells under axial load have been studied. The experimental program is included two groups: the first consists of nine cylinders; each has a diameter of 150 mm, while the height varies from 100 to 500 mm and thickness of 1.5 mm, test results show that the optimum height to achieve the maximum strength is 300 mm with L/D equal to 2. The second group consists of two cylinders with diameter of 150 mm and height of 300 and 500 mm strengthened with stiffeners plate welding from inside at four quarters with thickness of 1.5 mm and width 20 mm fabricated from the same metal of the cylinders. After testing these two cylinders were gain an increase in the strength reached to 42% for 300 mm cylinder and 26.4% for 500 mm cylinder. The failure modes for these two groups are: the buckling at bottom like “elephant’s foot” for cylinders height from 100 to 300 mm and “inelastic buckling” for cylinders height from 350 to 500 mm for the first group, and the ” inelastic buckling” for the second group.
CFDSST Concrete Filled Double-skinned steel tubular columns are composite columns consisting of two concentric circular steel tubes with concrete filler in between. Finite elements method is considered through the use of the computer program ABAQUS to model CFDSST columns numerically under cyclic axial compression. Damage plasticity model was considered to model the concrete while elastic-plastic model used to model the steel tubes. six CFDSST specimens and three ordinary Concrete Filled Steel Tubular (CFST) specimens were analyzed under static axial compression, while three CFDSST specimens were considered for analysis under cyclic axial compression. The numerical results were presented in terms of axial load axial strain displacement curves. It was found that the ultimate axial load carrying capacity calculated numerically in good agreement with that of the experimentally tested specimens. Also it was concluded that Damage plasticity model used for simulating the behavior of concrete and metal plasticity model used for simulating the behavior of steel produced accurate results as compared to the experimental results.
This paper deals with the elastic stability of a column bolted at its mid-height to a simply supported square plate and subjected to a concentrated load, using energy method. A uniform homogeneous column is assumed to be pinned at both ends. From symmetry considerations, half of the column is modeled by making the plate acting as a torsion spring on the column at its mid-height. The column length and cross-section, plate dimensions and thickness, and the material properties for the column and the plate catch the interest of the author. The problem is solved by using energy method and ultimately, the elastic buckling load is found. The analytical elastic buckling load is compared with a numerical solution obtained from finite element method using SAP2000. The numerical results agree with the analytical solution. The finite element model is refined to catch the actual effect of the bolted plate on the elastic buckling load. It has been found that the elastic buckling load is increased due to the increase in the rotational stiffness provided from the plate.
The mixing technique was applied in this study to enhance the strength performance of the cement. The addition of 3% by weight of hydroxyapatite (HA) nanoparticles were mixed with 97% polymethyl methacrylate (PMMA) acrylic polymer, which has a nano size to serve as the matrix material. The surface roughness and continuous porosity of the bone cement were found to be slightly increased by the incorporation of nanoparticles, which enhanced bone-implant osseointegration and ingrowth. Atomic force microscopy (AFM) analysis revealed that the addition of hydroxyapatite (HAp) nanoparticles resulted in a surface roughness value (Sa) of 16.25 nm, which is similar to that of natural bone. The energy-dispersive X-ray spectroscopy (EDS) mapping results discover precentor material and uniform distribution. The Sample exhibited promising results in the antibacterial test, showing efficacy against bacteria both with and without sterilization, confirming its antibacterial properties. The mechanical tests conducted on the sample, including tensile, compression, bending and Vickers hardness tests, yielded favorable results and indicated that the sample is suitable for its intended application. In the theoretical works the design of the bone, screw, and bone plate was conducted using SolidWorks, followed by an analysis using ANSYS under both axial and bending load conditions. The theoretical analysis revealed that the safety factor was less than 1 when an axial load of 13 N was applied and a bending load of 2 N was applied, indicating that the structure may not be able to withstand these loads safely. Under both ambient and physiologically relevant conditions in the human body, HA and PMMA have demonstrated to be excellent choices for enhancing the clinical performance of bone cement. This, in turn, can lead to increased longevity of implants, decreased patient risk, and lower healthcare costs