×
The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerHydraulic structures, including cascade aerators, may be acknowledged as important components in improving aeration efficiency because of the intense turbulent mixing combined with large air bubble entrapment at these structures. The main objective of the present study is to achieve maximum aeration efficiency and enhance the concentration of dissolved oxygen in the water since this is an important factor in improving water quality. The present study aims to determine the most proper geometric and dynamic parameters of a typical square-shaped stepped cascade with a total height of 120 cm, and sex steps. A tread of each step is 10 cm and a rise of each step is 20 cm, where aeration efficiency is maximized. The results of the study revealed that the maximum value of water aeration efficiency, meaning an increase in dissolved oxygen in the water using a stepped cascade aerator happened when flow rates of 15 L/min, 25 L/min, and 35 L/min with aeration efficiencies of 22%, 37%, and 42% respectively. Finally, the optimization of flow rates in aeration systems can lead to improved water quality parameters. The most important feature of the present study is the innovation of a natural method of water treatment that relies on the principle of mixing, coagulation, and flocculation by hydraulic methods, which works to reduce the costs of operation.
In this study sunlight and UV radiation were used to compare the efficiency of decolorization of textile wastewater containing brilliant reactive red dye K-2BP (?max = 534 nm) by the advanced oxidation process (AOP) using (H2O2/sunlight, H2O2/UV, H2O2/TiO2/sunlight, and H2O2/TiO2/UV). The results studied the effect of solution pH, applied H2O2 concentration, TiO2 concentration (nanoparticle), and initial dye concentration were studied. The experimental results showed that decolorization percentage with H2O2/sunlight and TiO2/H2O2/sunlight under the following conditions: - reaction time 150 of minutes, [ 500 ppm] H2O2, [100 ppm] TiO2, pH=3, initial dye concentration =15 ppm and at ambient temperature were 95.7% and 98.42% respectively. For the same conditions using H2O2/UV, H2O2/TiO2 /UV, the percentage of decolorization were 97.85% and 96.33% respectively. The results also indicated that the sunlight is more economic and cost-effective than UV radiation.
Basrah is the richest town and the economic capital of Iraq. It suffers from lack of drinking water. This project is a dream to supply drinking water to Basrah citizens within WHO standards. Water should pass sedimentation and filtration stages before interring reverse osmosis unit. The design is carried out using lewaplus2 software. Several parameters should be selected in the design step membrane type, number of stages, number per element in each stage, and the recovery percentage. An optimization is carried out using Minitab ver. 18 for the acceptable limit of TDS and minimum cost and it was found that the optimum conditions were 52% for first stage, the numbers of vessels are 20 for both the first and second stage. In addition, results showed that the pressure and the total dissolved solid increase with increasing the recovery while parameters like the feed flow rate per vessel, the power, and the cost are decreasing with the recovery. Mathematical model described the cost was conducted and statistical study was also done to ensure the results.