The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerThe aim of this work is to determine the optimum parameters for deposition of chitosan and mixture of chitosan and hydroxyapatite (HA) layers using electrophoretic deposition. The layers were on 316L stainless steel substrate. Taguchi approach was utilized to select the optimum parameters for both layers. The parameters used for deposition chitosan are voltage, time and temperature while the parameters used for HA and chitosan are voltage, time, concentration and temperature. Zeta potential tests were employed to measure the solutions stability. Coating layers were characterized for thickness, porosity and nanoroughness using optical microscopy (OM) and atomic force microscopy (AFM). The results from Taguchi design of experiments demonstrated that the best conditions for deposition of chitosan and HA layers are 50 V, 5 min, 3 g HA/L and 30°C. The corresponding thickness, % porosity, nanoroughness and microroughness for optimum conditions were 22 µm, 3.53, 4.48 nm and 3.85 µm respectively.
The aim of this work is to optimize EPD variables (voltage, time, and focus) using alternating current through the Taguchi Design of Experiment (DOE). Coating Nano hydroxyapatite (Nano-HA) on a Ti6Al4V substrate depends on thickness and roughness, then characterization of a coating layer to determine the optimum state. Hydroxyapatite (HAp) powder was deposited on a Ti-6Al-4V alloy substrate by electro-deposition with ethanol as a solvent under AC current, to improve the alloy surface quality based on coating thickness and maximum coating mass meeting the requirements of a biological orthopedics application. Ethanol was used as a solvent to precipitate ketazone and HAp on the base alloy. Taguchi's approach was used in order to determine the optimal conditions for EPD and subsequently to apply various criteria for depositing the biochemical coating. The surface and cross-section composition of the paint is described by characterization. Numerous tests and inspections; Zeta, XRD and SEM stability test, water contact angle and optical microscopes were used to describe the surface morphology of the HAp layer. The value of the optimum conditions for deposition of the HAp layer which is a simultaneous thickness and maximum coating mass, was predicted at a sedimentation voltage of 40 V, 2 min sedimentation time and 1 g / L for the concentration of the suspended solution at room temperature. The validity of the model resulting from the response surface methodology was assessed by comparing the expected results with the experimental results. In addition, close agreement was observed between the experimental results and the expected results. For the solution at room temperature, the results obtained with the highest value of the coating thickness of 41at the surface roughness of 0.94 and the contact angle of the alloy before coating is 67.489º reduced to. 38.132º after plating, which indicates an increase in the harmony of the metal implant and biocompatibility.