Al-Nahrain Journal for Engineering Sciences
Login
NJES
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Submission Resources
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
  • Policies
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Copyright Policy
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Abstracting and Indexing
    • Announcements
    • Contact

Search Results for sensors

Article
Piezoelectric Fixing Direction effect on GRF test results in Wearable Shoe-Insole System

Ammar Issam Salih Kubba

Pages: 152-158

PDF Full Text
Abstract

This article is about studying the placing direction effect of a piezoelectric sensor on the shoe insole in the GRF results. Where the sensors used in this research are in two directions, along and perpendicular to the foot midline. In the both cases the sensors were fixed on the shoe insole to sense the foot pressure. For the first set of sensors which are perpendicular to the foot midline the collected data has similar trend to the GRF collected from the force plate, as the small lateral strain in the shoe insole due to the patient weight and GRF is close to the GRF data collected from other measurement system. On the other hand, the collected data from the second set of sensors which are in a longitudinal direction with the foot midline will have different trend and values from the collected data from the force plate or any other GRF measurement system. This different in the results is due to the large longitudinal strain in the shoe insole due to the patient weight which produce dissimilar results from the force plate result data.

Article
Intelligent Controller for Monitoring Vehicles at the Roads

Hussein A. Mohammed, Alaa Hamza Omran, Ahmed Raheem, Yaser M. Abid

Pages: 1207-1214

PDF Full Text
Abstract

Many mobile applications use infrared (IR) and Ultrasonic sensors for distance measurements. In this paper, these two types of sensors have been used in building obstacle detection system and the attributes of each sensor has been tested, the system consists of transmitter and receiver circuit, furthermore, Arduino UNO card has been used for transmitting and receiving signal for each type of sensor based on the Arduino software. The test was performed through distributing these sensors on the road then analyze the reflected signal. Neural network trained and used for monitoring the street and producing the number of cars in each line of street and the total number of cars in the same street.

Article
Study the Effect of Using Different Bearing Types on the Performance of Evaporative Cooler

Shaker S. Hassan, Ahmed Adnan Shandookh, Omar Alaa Ihsan

Pages: 532-538

PDF Full Text
Abstract

An investigation of performance response of two types of bearings such as Cylindrical Roller Bearing and bush bearing on evaporative cooler driven by DC motor of 1500 r.p.m, through studying many parameters like vibration response, temperature raise, humidity, sound level and total performance. high quality 3D positions X, Y and Z, vibration sensors type (ADXL335 accelerometers) with Arduino mega 2560 that interfaced with Lab-View program were used to measure changes in vibration amplitude and frequency. Two temperature sensors of type (LM35) were used to investigate the temperature raise in the bearings also with Arduino mega 2560 that interfaced with Lab-View program. For humidity a sensor of type DHT22 was used, also, a portable device was used to measure electricity consumption, rotary speed and sound level in the bearings of evaporative cooler. By replacing bearings all the parameters above wear measured then a comparison between them were made to find the best performance and operation of these bearings. The obtained results from the experimental work have clarified and explained by tables and figures. It has been found that the vibration of evaporative cooler in X, Y and Z-directions increased by using two cylindrical roller bearings than using two of bush bearings. The temperature of cylindrical roller bearings increased When running the evaporative cooler more than bush bearings. the noise of Evaporative Cooler by using both types of Bearings was almost same but with a little Reduce by using cylindrical roller Bearings. Which means the Evaporative Cooler has better Performance by using bush bearings than using cylindrical roller bearings.

Article
Performance Evaluation of Gesture Recognition Using Myo Armband and Gyroscope Sensors

S. M. Sarhan, M. Z. Al-Faiz, A. M. Takhakh

Pages: 461-468

PDF Full Text
Abstract

The technique of recording muscle signals is crucial in determining how effectively they can be utilized for individual benefit. This study focuses on hand movements recognized by using the Myo armband and Motion Processing Unit (MPU) 6050 sensors. Linear Discriminant Analysis (LDA), K-nearest neighbors (k-NN), and Support Vector Machine (SVM) were employed for classification. sEMG signals using the Myo armband for 7 hand gestures and 2 elbow movements were recorded from 10 healthy subjects. Results showed that SVM outperforms LDA and k-NN in accuracy in both cases, the sensor is worn once on the arm and again on the forearm. regions. The window size and choice of features significantly influence system accuracy, with SVM achieving an average accuracy of 89.84%. Besides that, the fusion of Myo Armband sensor and gyroscope sensor through OR rule makes significant enhancement in recognition accuracy with which is reached to 97.0135%. In conclusion, the Myo armband, when worn on the forearm, proves practical for hand gesture recognition, with SVM offering superior recognition accuracy. Furthermore, the combination of the Myo Armband sensor and the gyroscope sensor showed higher recognition accuracy.

Article
Monitoring and Control on Impressed Current Cathodic Protection for Oil Pipelines

Jasim A. Harbi, Furat I. Hussein, Laith A. Sabri

Pages: 807-814

PDF Full Text
Abstract

This research is devoted to design and implement a Supervisory Control and Data Acquisition system (SCADA) for monitoring and controlling the corrosion of a carbon steel pipe buried in soil. A smart technique equipped with a microcontroller, a collection of sensors and a communication system was applied to monitor and control the operation of an ICCP process for a carbon steel pipe. The integration of the built hardware, LabVIEW graphical programming and PC interface produces an effective SCADA system for two types of control namely: a Proportional Integral Derivative (PID) that supports a closed loop, and a traditional open loop control. Through this work, under environmental temperature of 30°C, an evaluation and comparison were done for two types of controls tested at low soil moisture (48%) and high soil moisture (80 %) to study the value of current, anode voltage, pipe to soil potential (PSP) and consumed power. The results show an decrease of 59.1% in consumed power when the moisture changes from the low to high level. It was reached that the closed loop controller PID is the best solution in terms of efficiency, reliability, fast response and power consumption.

Article
The Seismic Response of a Shallow Foundation Supported on Geogrid-Reinforced Sand Soil

Ruqayah Al-khafaji, Qassun S. Mohammed Shafiqu

Pages: 481-492

PDF Full Text
Abstract

Shallow foundation suffers from considerable settlement, displacement and tilting under earthquakes. This is particularly due to the shaking associated with earthquakes that lead to the generation of horizontal seismic load transferred through the soil to the foundation. Also, liquefaction could take place during the earthquake in the saturated loose sand. To alleviate the detrimental effect of earthquakes, ground improvement is required. This study examines the response of the shallow square foundation rested on loose sand soil reinforced with geogrid reinforcement when subjected to 2023 Turkey earthquake by using a shaking table system. Different number of geogrid layers are installed; (one, two, three and four), also various geogrid configurations were examined which are (straight, trapezoidal and reverse trapezoidal). The acceleration response, settlement, horizontal displacement, rotation and pore water pressure developed in the sand soil and the shallow foundation during 2023 Turkey earthquake has been examined. The settlement and the horizontal displacement, foundation rotation, acceleration and pore water pressure were measured using rope displacement transducers, tilt sensors, accelerometers and pore water transducers respectively.  The results showed that the acceleration amplifies when passing through loose sand. The results also indicated that the shallow foundation experienced noticeable settlement, horizontal displacement and rotation when subjected to the seismic loads. On the other hand, the installation of geogrid proved to be effective in controlling the problems associated with earthquakes. The optimum geogrid reinforcement is occurred when three layers of geogrid placed in reverse trapezoidal configuration (3RT) since it gave the best reduction in the acceleration amplification and the highest decrease in the foundation settlement, displacement and tilting which is about (60-66) %. Nevertheless, the effectiveness of geogrid minimizes when the sand soil becomes saturated. In addition, liquefaction occurs during earthquakes especially at the shallower depths because of the decrease in the shear strength of saturated soil.  

Article
Vibration Characteristics of the Bearing Rotor Shaft

Karrar Baher, Qasim A. Atiyah, Imad A. Abdulsahib

Pages: 49-54

PDF Full Text
Abstract

In this work, the vibrations in the rotor-bearing system are studied experimentally and theoretically using ANSYS Workbench 2020 R1 software to compute the natural frequencies and mode shapes. In the experimental part, the LABVIEW software was used to examine the signal of the frequency domain values obtained from the accelerometer sensors, based on Fast Fourier Transform (FFT) technology and dynamic response spectrum. in the theoretical part, the natural frequencies are determined based on the finite element method for analyzing the system and knowing its behavior and vibration response level. The results showed that the level of vibration becomes higher at high rotational speeds, and it becomes large when the distances between the bearings are large, according to the bearing position and type used in the system. in this work can be concluded, the system is usually affected by the dynamic response around it and is difficult to separate from it, and the vibrations in the system can be controlled by adding an external damping source, which gives the system more stable. A system operating at high speeds can give a large vibration and an unbalanced response.

Article
Performance Optimization of Cylindrical WGM Microresonator Sensors for Various Delivery Fiber Diameters

Esraa A. Hassan, Alhuda A. Al-mfrji, Aseel I. Mahmood

Pages: 573-580

PDF Full Text
Abstract

Whispering Gallery Mode Micro-Resonators (WGMRs) have received significant interest due to their great sensitivity to environmental changes, compact size, and ability to operate over a wide spectral range because their low optical losses produce high-quality factors so that they can be used in various sensing applications. This work investigates the design and implementation of cylindrical WGMRs for Refractive Index (RI) sensing for different delivery fiber diameters.  Single Mode Fiber with different waist diameters (80,67.1,18) µm were used as delivery fibers. At the same time, the sensor (resonator) fiber is SMF with a diameter (125 µm). Quality factors and Free Spectral Range (FSR) were calculated and analyzed for each diameter. The quality factor for all diameters was in power of 104, which is considered good. The FSR is inversely proportional to fiber diameter. FSR values were (0.678,1.75,2.03) nm for (80,67.1,18) µm delivery fiber diameters respectively.  An analyte prepared by NaCl with different refractive indices is used to investigate the RI sensor performance. Higher sensitivity is obtained from the WGMR with a smaller waist diameter, which is (-)74 nm/RIU. While for the delivery fiber diameters (80,67.1) µm were (-0.28, -9.27) nm/RIU respectively. The submitted sensor will have a good contribution in the field of chemical, biological and medical applications.

1 - 8 of 8 items

Search Parameters

×

The submission system is temporarily under maintenance. Please send your manuscripts to

Go to Editorial Manager
Journal Logo
Al-Nahrain Journal for Engineering Sciences (NJES)

College of Engineering, Al-Nahrain University

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY NC 4.0 Logo Licensed under CC-BY-NC-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

Copyright © 2026 College of Engineering, Al-Nahrain University, its licensors, and contributors. All rights reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.