Al-Nahrain Journal for Engineering Sciences
Login
NJES
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Submission Resources
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
  • Policies
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Copyright Policy
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Abstracting and Indexing
    • Announcements
    • Contact

Search Results for plasma

Article
Experimental Investigations of the Plasma Arc Cutting of AISI 1020 Carbon Steel Plate

Samer Jasim Mahmood Algodi, Abdulhakeem Amer Salman

Pages: 193-198

PDF Full Text
Abstract

The current study presents the plasma cutting process of 2 mm thickness of AISI 1020 carbon steel. The experiment conducted by taking into the account the effect of two process parameters, including cutting current of 15 and 20 A with cutting speed in range of 500 - 4000 mm/min, on the kerf formation, microstructure and microhardness.The results showed that at low cutting current of 15 A the melting occurred at the workpiece surface without cutting action. Increase the current to 20 A led to full penetration of the workpiece material at low and high cutting speed, with kerf width between 1.26 mm and 1.1 mm for cutting speed of 500 mm/ min and 4000 mm/ min, respectively. The plasma arc cutting speed has a high impact on the heat-affected zone HAZ and microstructure development with coarse grains at the HAZ at low cutting speed of 500 mm/min and constant current of 20A, increase the plasma cutting speed led to decreasing the grain size. The microstructure of the HAZ exhibited a presence of perlite and ferrite with some martensite structure. The highest microhardness of the HAZ of 220.8 HV was found in the sample processed at 20 A current and high cutting speed of 4000 mm/ min. However, the minimum microhardness of the HAZ of 156.7 HV was found in the sample processed at 20 A current and low cutting speed of 500 mm/ min.

Article
Enhancing Emission Intensity of Spectral Lines Ti I Using Nanoparticle enhanced laser-induced breakdown spectroscopy (NELIBS)

Noor Kefah Noory, Tagreed Hamad, Salam A. W. Al-abassi

Pages: 347-350

PDF Full Text
Abstract

Enhanced signal emission from nano (ESEN) coated titanium target over than that from normal untreated one was investigated. Four samples of Ti alloy were adjusted, the first sample was left untreated, the second and third samples were coated with plasma sputter at thicknesses of 35nm and 70nm, and the last sample was treated with a drop of colloidal Au nanoparticle solution prepared by laser ablation. The (ESEN) was monitored with Ti   at 413.7 and 393.3 nm. It was obtained that the spectral emission from the nano-laser ablation had a greater improvement than that from the plasma sputter coating or bulk target. Enhancement factors were found up to ten folds, and show the spectroscopic line induced patterns by laser energies (100,150, and 200mJ) from the alloy  with and without gold.

Article
Comparative Study of Compartmental Modeling of Sustained Release Oral Dosage Forms and Intramuscular Injection

Khawla H. Rasheed

Pages: 222-226

PDF Full Text
Abstract

This study has been performed to compare the compartmental modeling of two types of extravascular routes, sustained-release (SR) oral dosage forms and intramuscular (IM) injection. Twenty healthy volunteers received a single dose of 100 mg Diclofenac Sodium (DS) sustained-release tablet, then 75 mg DS Intramuscular injection after two weeks washout period. The concentrations of DS in plasma were measured using reverse-phase high-performance liquid chromatography (HPLC). The data analyzed using compartmental modeling, with single time-variant input and output. Primary kinetic parameters for both formulations, ( , , ) and other kinetic parameters were evaluated. The result shows that the IM injection needs a shorter time to reach the maximum concentration with convergent bioavailability to SR oral dosage forms, in another hand the data of IM injection fitted to single-compartment model with a correlation coefficient of 0.93 and the data of SR tablet fitted to two-compartment models with a correlation coefficient of 0.97.

1 - 3 of 3 items

Search Parameters

×

The submission system is temporarily under maintenance. Please send your manuscripts to

Go to Editorial Manager
Journal Logo
Al-Nahrain Journal for Engineering Sciences (NJES)

College of Engineering, Al-Nahrain University

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY NC 4.0 Logo Licensed under CC-BY-NC-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

Copyright © 2026 College of Engineering, Al-Nahrain University, its licensors, and contributors. All rights reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.