The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerIn the present work the effect of Corrosion & Scale Inhibitor was evaluated by using of the commercial product (Kurita S2050) that mainly containing of (Na2HPO4) sodium phosphate as corrosion inhibitor and (C6H11NaO7) sodium glocunate as scale inhibitor & dispersant. The dosing rate of this chemical was controlled according to the treatment system depend mainly on the monitoring of LI & RI indexes for (30) days treatment in the cooling tower unit of Al-Dora Oil refinery-Baghdad. The corrosion rate and the corrosion inhibitors efficiency were calculated by measurement of weight loss in standard test coupon (AISI 1010). After 30 day of the Field Test, the result show that the treatment program performance was effective in the corrosion & scale inhibition through an acceptable corrosion rate less than 0.018 in gmd. Also the result of corrosion rate was analyzed statistically by using of (ANN) to formulate a prediction equation to corrosion rate identification.
In this paper, the efficiency of six different types of corrosion inhibitors used in Basrah drinking water tanks was assessed using a potentiostatic test method. The mechanism of adsorption of silicate and phosphate inhibitors in AISI 316 stainless steel surfaces and the effects of different water components in inhibitors are discussed in detail. The values of corrosion rate obtained from the Potentiostatic test showed that the protection against corrosion in the presence of inhibitors is better compared to the case of absence of inhibitors. The results of the six types of corrosion inhibitors tested showed that the inhibitory efficacy is higher below the temperatures 45oC, but when raise the temperature above 45oC the inhibitory efficiency becomes to decrease. Also, the test results indicated that the corrosion inhibitor involves silicate products provided more inhibited efficiency compared to the phosphate inhibitor alone or used the combined silicate/phosphate corrosion inhibitor. The inspection of the surface of the tested samples using optical methods shows that the pitting corrosion is demonstrated on the specimen surfaces after testing with or without inhibitors.
The impact of flow velocity (0-900 rpm) on the corrosion rate of carbon steel in a wide range of sulfuric acid concentrations (0-90% in H2O) at 30 °C and 1 h was studied and discussed. In addition, the efficiency of corrosion inhibitor (dimethyl disulfide, DMD) was evaluated in hardest corrosion conditions for the range of velocity investigated. The results revealed that increasing the flow velocity of H2SO4 solution, increases the corrosion rate depending on the acid concentration. When the flow velocity is increased of H2SO4 solution, the corrosion potential was shifted to more negative. The DMD inhibitors showed significant inhibition efficiency at high velocities, where the highest percentage of inhibitor efficiency reached 98% at 900 rpm.