Go to Editorial ManagerThis paper presents experimental investigations to study the behavior of High Strength Reinforced Concrete (HSRC) deep beams with web openings under monotonic and static repeated loading conditions. The experimental work procedure consisted of testing eighteen simply supported HSRC deep beams both with and without web openings. The numerical work procedure consisted of testing ten simply supported HSRC deep beams both with web openings. All beams had the same dimensions and flexural reinforcement. They had an overall length of 1400 mm, a width of 150 mm and a height of 400 mm. The investigated test parameters were concrete compressive strength, shape and size of openings, vertical and horizontal reinforcement ratios, shear span to effective depth ratio (a/d ratio) and loading history. The experimental results reveal that the ultimate load capacities for specimens tested under four different repeated loading regimes decrease in the range between 2% and 19% in regards to the control specimens which were tested under monotonic loading regime. The results indicated that the increase in the severity of loading history leads to a decrease in the ultimate shear strength of the deep beams and causes increases in their ductility ratio. The ultimate loads of HSRC deep beams with square web openings size of (50*50mm, 60*60mm and 70*70mm) tested under the repeated loading history (HS-1) which consisting of five phases decreased by (11.4 %, 24.1% and 26.3 %, respectively) compared to that of identical solid deep beam. The ultimate load of HSCR deep beam with circular web openings shape tested under repeated loading history (HS-1) increases by 8.6 % compared to the equivalent square web openings shape. For numerically analyzed beams under repeated loading history (HS-1), the ultimate load increases by 16% when using area of 2500mm2 of circular web openings shape (equal in area to square web opening size 50mm*50mm) and by 13.5% when using rhombus web openings shape of the dimensions 50*50mm in comparison with the case of 60-mm size square web openings.
This paper presents a simple strut and tie model to calculate the shear strength of reinforced concrete deep beams. The proposed model assumes that the shear strength is the algebraic sum of three strength components: concrete diagonal strut, vertical stirrups, and horizontal web reinforcements. The contribution of each strength components was calibrated with the test results of 305 deep beams compiled from previous studies with wide range of geometrical and material properties. The predictions of the proposed model were compared with those of the current codes of practice (ACI-318-14 and ASHTOO 2014) and those of existing model in the literature. Comparisons revealed that the proposed model provided better predictions than other models. The mean of predicted strength to test of the proposed model, the ACI-318-14 model, the ASHTOO 2014 model were 0.98, 0.79, and 0.75, respectively. The corresponding standard deviations were 0.17, 0.28, and 0.49, respectively.
Numerical analysis of the performance of reinforced concrete (RC) deep beam subjected to static and fixed-point pulsating loading at the midpoint has been investigated. Three-dimensional nonlinear finite element model using the Strut and Tie approach was adopted. The damage level under the influence of the applied fixed pulsating loading is higher than the static applied loading, hence early crack was observed because of the stepwise loading in the form of vibration. Although the Strut and Tie approach gave a good estimation of the resistance capacity of the beam, the beam undergo high shear damage when subjected to these two types of loading. Material strength properties, applied loadings and cross-sections adopted are some of the factors that affect the performance of the deep beam.