The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerThis study examines the flow behavior and lift coefficient variations of a NACA 4415 airfoil using different vortex generator configurations. Experimental investigations are conducted in a subsonic wind tunnel at a Reynolds number of 1.8 x 105. The airfoil is tested with two types of vortex generators, namely the dome vortex and the convergent-divergent vortex, positioned at 10%, 28%, and 60% chord locations. Experimental lift coefficients are compared with Airfoil Tools database, showing consistent agreement within an angle of attack range of 0 to 18 degrees. At small angles of attack (0 to 8 degrees), the lift coefficients of the NACA 4415 airfoil with the dome vortex at 10%, 28%, and 60% chord positions are lower compared to the baseline configuration. However, beyond 14 degrees, the highest lift coefficient value after the angle range of 14-18 degrees is achieved at the 60% chord position with the dome vortex, 10.43% increase compared to the baseline lift coefficient. Furthermore, the best value for the lift coefficient after the angle range of 16-18 degrees at the 10% chord position is achieved with the dome vortex, where the maximum lift coefficient 9.4% increase compared to the baseline lift coefficient. It is noted that the baseline configuration consistently outperforms the convergent-divergent vortex configurations.
The purpose of this research is to investigate how the fiber orientation and loading axis of a composite material affect its behavior. Consideration was given to two different fiber-to-matrix ratios in order to improve the mechanical properties. Hand lay-up samples were produced in accordance with ASTM D790 for flexural testing. On UTM, tensile and flexural tests were performed on the sample. The effect of fiber orientation modifies the composites' mechanical properties. As the fiber orientation increased, the tensile strength of the composite would reduce. This carbon/epoxy composite test demonstrates better strength than those conducted at (30, 5, 60, and 90 degrees). For flexural tests, a three-point bend at 30 degrees demonstrates excellent strength. Utilizing the three-point bend method, the flexural strength and flexural modulus have been determined. The tensile strength, young's modulus, elongation percentage, maximum load to break the composite, peak load, and flexural strength of single- and double-layered carbon fibers were compared and examined. As the number of layers increased, the adhesion between layers of epoxy and fiber carbon, and glass fiber weakened, causing a decrease in almost all mechanical properties. The fabricated 2024-T3 and epoxy glass fiber had higher fatigue strength than aramid reinforced and lower density than steel alloy utilized in aircraft manufacture.