Vol. 21 No. 4 (2018) Cover Image
Vol. 21 No. 4 (2018)

Published: December 31, 2018

Pages: 467-472

Articles

Deposition Hydroxyapatite /Titania Composite on Ti-6Al-7Nb Alloy for Human Body Implants

Abstract

The microstructural analysis and electrochemical measurements tests were used to investigate the behaviors of (TiO2) and (HAp)-coated Ti-6Al-7Nb alloy in the SBF solution .By using RF sputtering, a thin TiO2 layer coated  the substrate, while a thick layer of HAp coated the outer side of surface. The generated middle layer consist of  the  composite of TiO2 and HAp which is by AFM characterized as uniformly distributed coating system with nano size. The images of the scan electron microscopy (SEM) shows that there is no any cracking observed in the outer layer of tested samples due to the use of thin film TiO2 as mid lead to reduce the difference in the thermal expansion between the HAp material and Ti-6Al-7Nb substrate .The HAp upper layer significantly improve the bioactivity of the Ti-6Al-7Nb alloy. In this study, the bonding strength and the corrosion resistance was improved by using thin layer of TiO2. From electrochemical impedance spectroscopy (EIS) study Bod plot, the composite layer of TiO2 and HAp was suggested by the capacitive act as barrier layer coated substrate and prevent the relays of the ion from metallic. The results shows the values of Rox (309.2 k? cm2)are greater than for Rct(19.2 k? cm2), by assumes the presence  oxide film increases for coated substrate are greater than that of uncoated, which is a result of the presence of coated film that improve the corrosion resistance of the sample.

References

  1. Sittig. M. T, Spencer. N.D, Wieland. M, Vallotton .P.H" Corrosion Behavior of Ti-6Al-7Nb Alloy in Biological Solution for Dentistry Applications ", J. Mater. Sci.: Mater. Med. Vol .10, No.2, 199.
  2. El-Taib. F, Awad .Kh.A." lectrochemical Corrosion and Passivation Behavior of Titanium and Its Ti-6Al-4V Alloy in Low and Highly Concentrated HBr Solutions, "Int. J. Electrochem. Sci., Vol.6, No.1, pp.6483 – 6502, 2011.
  3. Wua. C, Ramaswamy. Y" Novel sphere coatings on Ti–6Al–4V for orthopedic implants using sol–gel method, "Acta Biomaterialia, Vol.4, No.11, pp. 569–576, 2008.
  4. Bolat .G, Mareci. D, Iacoban .S, "The Estimation of Corrosion Behavior of NiTi and NiTiNb Alloys Using Dynamic Electrochemical Impedance Spectroscopy" Hindawi Publishing Corporation.J. Spectroscopy, Vol.1, No.12, pp.1-7, 2013.
  5. Mohan .L, Durgalakshmi .D, Geetha .M, Sankara Narayanan .T.S"Electrophoretic deposition of nanocomposite (HAp + TiO2) on titanium alloy for biomedical applications" Elsevier, Ceramics International ,Vol.38,pp. 3435–3443,2012.
  6. Kim H, Hag Koh Y, Hao Li. L, Lee. S, Kim. H. Ee "Hydroxyapatite coating on titanium substrate with titania buffer layer processed by sol–gel method" Elsevier, Biomaterials, Vol. 25, No.2, pp.2533–2538, 2004.
  7. Škugor Rončević I., Grubač Z, Metiko .M, "Electrode position of Hydroxyapatite Coating on AZ91D Alloy for Biodegradable Implant Application", Int. J. Electrochem. Sci., Vol. 9, pp. 5907 – 5923, 2014.
  8. Wei .C. H, Lu .C.T, Sue .W. C, Chang .C. M "Analysis of Surface Property of TiO2 Thin Film Prepared by Sputtering, Tacking, "Journal of Science and Engineering, Vol.10, No.2, pp. 177-181, 2007.
  9. Kim. S. C, Chan Heo. M., Hong Hahn .S, "Photocatalytic Activity of Pd-Doped TiO2 Thin Films by Using a RF Magnetron Co-Sputtering Method, "Journal of the Korean Physical Society, Vol.47, No. 4, pp. 700-704, 2005.
  10. De Souz .M. E, Ariza .E, Ballester. M, Yoshida. I. V, Rochab L. A, Freire. C. M" Proceedings of International Corrosion "Materials Research, Vol.9, No.1, pp.59-64, 2006.
  11. Ding .S"Properties and immersion behavior of magnetron-sputtered multi-layered hydroxyapatite/titanium composite coatings" Journal of Biomaterials, Vol.24 No.3, pp.4233–4238, 2003.
  12. Fomin .A. A, Steinhauer .A. B, Rodionov. I. V, Petrova .N. V, Zakharevich.A. M. "Nanostructure of Composite Bioactive Titania Coatings Modified with Hydroxyapatite in Medical Titanium Implants, "Biomedical Engineering, Vol.47, No.3, pp.138_141, 2013.
  13. Podhorodecki, A., Zatryb G., Misiewicz. J, Domaradzki J, Kaczmarek. D"Influence of Annealing on Europium Photoexcitation Doped into Nanocrystalline Titania Film Prepared by Magnetron Sputtering" Journal of The Electrochemical Society, Vol.156 No.3 H214-H219 ,pp.0013-4651,2009.
  14. Tamilselvi. S, Raman .V, Rajendran .N, Electrochimica Acta Vol.52, No.1, pp.839–846, 2006.
  15. F. El-Taib Heakal, A. A. Ghoneim and A. Fekry, J. Appl. Electrochem. , vol.37, pp. 405-413, 2007.
  16. Heakal F. El, Mogoda A. S, Mazhar .A.A, El- Basiouny M. S., Corros. Sci., Vol.27, pp.453-4462, 1987.
  17. Schutz .R, "An Overview of Beta Titanium Alloy Environmental Behaviour, in Beta Titanium Alloy ", The Mineral, Metals & Materials Society, pp. 75-91.1993.
  18. Casillas .N, Charlebois S, Smyrl. W. H, White H. S, "Effects of Pores on Mechanical Properties of Plasma-Sprayed Ceramic Coatings" J. Electrochem. Soc., Vol.141, pp.636-642, 1994.