Vol. 20 No. 3 (2017) Cover Image
Vol. 20 No. 3 (2017)

Published: June 30, 2017

Pages: 625-635

Articles

Strengthening and Retrofitting of Reinforced Concrete Hollow Columns using High Strength Ferrocement Fibers Composites

Abstract

Eight RC circular hollow columns (external diameter = 220 mm, internal diameter = 100 mm, length = 1000 mm and the hollow part = 700mm) casted and strengthened with ferrocement fibers composites to illustrate the behavior of these columns under concentric and eccentric axial compression force. Two columns where used as reference columns, which were repaired after failure to be tested as retrofitted columns. Six specimens were strengthened with one and two WWM layers as required. The variables considered included number of the WWM layers (N), the loading configuration and the eccentricity value (e) of loading. The ferrocement thickness was constant at 20 mm in all retrofitted and strengthened specimens.The test results revealed that the maximum increase in the ultimate concentric loads were 67% by strengthening the reference column with two layers of WWM, and the maximum increase in the ultimate eccentric load of columns was 78% by increasing of the WWM from one to two layers. For a constant number of WWM layers, the change from concentric to eccentric force caused a decrease in the ultimate load value attaining 73.5% for one- layer WWM strengthened columns. The failure of columns occurred by yielding of steel reinforcement followed by concrete crushing (i.e. tension failure).

References

  1. Kaminski, M., and Trapko, T., (2006), "Experimental Behavior of Reinforced Concrete Column Models Strengthened by CFRP Materials," Journal of Civil Engineering Management, Vol. 12, No. 2, pp. 109-15.
  2. Waghmare, S. P B., (2011), "Materials and Jacketing Technique for Retrofitting of Structures," International Journal of Advanced Engineering Research and Studies, Vol. 1, Issue 1, E-ISSN2249 - 8974, pp. 15-19.
  3. ACI Committee 549 (1997), "State-of-The-art Report on Ferrocement (ACI 549.1R-97)," American Concrete Institute, Detroit.
  4. Shah, S. P. and Naaman, A. E., (1978) "Crack control in ferrocement and its comparison with reinforced concrete," Journal of Ferrocement, Vol. 8, No. 2, pp. 67-80.
  5. Razvi, S., and Saatcioglu, M., (1989), "Confinement of reinforced concrete columns with welded wire fabric," ACI Structural Journal, Vol. 86, pp. 615-23.
  6. Takiguchi, K., (2003), "An investigation into the behavior and strength of reinforced concrete columns strengthened with ferrocement jackets," Cement and Concrete Composites, Vol. 25, No. 2, pp. 233-42.
  7. Shahzada, K., Alam, B., Javed, M., Ali, Z., Khan, H. and Shah, S. S. A., (2012), "Retrofitting of Brick Masonry Columns by Ferocementing," International Journal of Advanced Structures and Geotechnical Engineering, Vol. 01, No. 02, pp. 50-54.
  8. AL-Sulyfani, B. J., Mahmood, M. N. and Abdullah, S. M., (2013), "Influence of Number of Wire Mesh Layers on the Behavior Strengthened Reinforced Concrete Columns," Al-Rafidain Engineering, Vol. 21, No. 5, pp. 80-91.
  9. Sirimontree, S., Witchayangkoon, B. and Lertpocasombut, K., (2015), "Strengthening of Reinforced Concrete Column via Ferrocement Jacketing," American Transactions on Engineering and Applied Sciences, Vol. 4, No. 1, pp. 39-47.
  10. American Specification for Testing and Materials, ASTM, (2000), "Standard specification for Portland cement," C 150 - 00.
  11. American Specification for Testing and Materials, ASTM, (2003), "Standard Specification for Concrete Aggregates," C 33 - 03.
  12. American Specification for Testing and Materials, ASTM, (2003), "Standard Specification for Deformed and Plain Billet-Steel Bars for Concrete Reinforcement," A 615M/A 615 - 03.
  13. American Specification for Testing and Materials, ASTM, (2000), "Standard Test Method for Slump of Hydraulic-Cement Concrete," C 143/C 143M - 00.
  14. American Specification for Testing and Materials, ASTM, (2001), "Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens," C 39/C 39M - 01.
  15. Don Construction Products (DCP), (2010), "Product Catalogue," third edition, 795pp.
  16. American Specification for Testing and Materials, ASTM, (1999), "Standard Specification for Latex Agents for Bonding Fresh to Hardened Concrete," C 1059 - 99.
  17. American Specification for Testing and Materials, ASTM, (1999), "Standard Test Method for Bond Strength of Latex Systems Used with Concrete by Slant Shear," C 1042 - 99.